_id: '12402'
abstract:
- lang: eng
  text: In anaerobic technology, pH values are crucial for targeted volatile fatty
    acid production. While pH dynamics can be modeled using the Anaerobic Digestion
    Model No. 1 (ADM1), simulation results may be biased. To address this issue, the
    pH prediction routine of Visual Water, a specialized water chemistry simulator,
    was validated. Unlike ADM1, it accounts for ionic strength and activities while
    also providing an automated uncertainty analysis. The analysis revealed Visual Water
    simulations to better fit measured pH data from acidic solutions in a miniaturized
    stirred-tank reactor.
author:
- first_name: Pascal
  full_name: Kosse, Pascal
  last_name: Kosse
- first_name: Tanja
  full_name: Hernández Rodriguez, Tanja
  id: '52466'
  last_name: Hernández Rodriguez
- first_name: Björn
  full_name: Frahm, Björn
  id: '45666'
  last_name: Frahm
- first_name: Manfred
  full_name: Lübken, Manfred
  last_name: Lübken
- first_name: Marc
  full_name: Wichern, Marc
  last_name: Wichern
citation:
  ama: Kosse P, Hernández Rodriguez T, Frahm B, Lübken M, Wichern M. Comparative Analysis
    of pH Prediction Routines in ADM1 and a Specialized Water Chemistry Simulator.
    <i>Chemie Ingenieur Technik</i>. 2024;96(4):528-534. doi:<a href="https://doi.org/10.1002/cite.202300188">10.1002/cite.202300188</a>
  apa: Kosse, P., Hernández Rodriguez, T., Frahm, B., Lübken, M., &#38; Wichern, M.
    (2024). Comparative Analysis of pH Prediction Routines in ADM1 and a Specialized
    Water Chemistry Simulator. <i>Chemie Ingenieur Technik</i>, <i>96</i>(4), 528–534.
    <a href="https://doi.org/10.1002/cite.202300188">https://doi.org/10.1002/cite.202300188</a>
  bjps: <b>Kosse P <i>et al.</i></b> (2024) Comparative Analysis of PH Prediction
    Routines in ADM1 and a Specialized Water Chemistry Simulator. <i>Chemie Ingenieur
    Technik</i> <b>96</b>, 528–534.
  chicago: 'Kosse, Pascal, Tanja Hernández Rodriguez, Björn Frahm, Manfred Lübken,
    and Marc Wichern. “Comparative Analysis of PH Prediction Routines in ADM1 and
    a Specialized Water Chemistry Simulator.” <i>Chemie Ingenieur Technik</i> 96,
    no. 4 (2024): 528–34. <a href="https://doi.org/10.1002/cite.202300188">https://doi.org/10.1002/cite.202300188</a>.'
  chicago-de: 'Kosse, Pascal, Tanja Hernández Rodriguez, Björn Frahm, Manfred Lübken
    und Marc Wichern. 2024. Comparative Analysis of pH Prediction Routines in ADM1
    and a Specialized Water Chemistry Simulator. <i>Chemie Ingenieur Technik</i> 96,
    Nr. 4: 528–534. doi:<a href="https://doi.org/10.1002/cite.202300188">10.1002/cite.202300188</a>,
    .'
  din1505-2-1: '<span style="font-variant:small-caps;">Kosse, Pascal</span> ; <span
    style="font-variant:small-caps;">Hernández Rodriguez, Tanja</span> ; <span style="font-variant:small-caps;">Frahm,
    Björn</span> ; <span style="font-variant:small-caps;">Lübken, Manfred</span> ;
    <span style="font-variant:small-caps;">Wichern, Marc</span>: Comparative Analysis
    of pH Prediction Routines in ADM1 and a Specialized Water Chemistry Simulator.
    In: <i>Chemie Ingenieur Technik</i> Bd. 96. Weinheim, Wiley (2024), Nr. 4, S. 528–534'
  havard: P. Kosse, T. Hernández Rodriguez, B. Frahm, M. Lübken, M. Wichern, Comparative
    Analysis of pH Prediction Routines in ADM1 and a Specialized Water Chemistry Simulator,
    Chemie Ingenieur Technik. 96 (2024) 528–534.
  ieee: 'P. Kosse, T. Hernández Rodriguez, B. Frahm, M. Lübken, and M. Wichern, “Comparative
    Analysis of pH Prediction Routines in ADM1 and a Specialized Water Chemistry Simulator,”
    <i>Chemie Ingenieur Technik</i>, vol. 96, no. 4, pp. 528–534, 2024, doi: <a href="https://doi.org/10.1002/cite.202300188">10.1002/cite.202300188</a>.'
  mla: Kosse, Pascal, et al. “Comparative Analysis of PH Prediction Routines in ADM1
    and a Specialized Water Chemistry Simulator.” <i>Chemie Ingenieur Technik</i>,
    vol. 96, no. 4, 2024, pp. 528–34, <a href="https://doi.org/10.1002/cite.202300188">https://doi.org/10.1002/cite.202300188</a>.
  short: P. Kosse, T. Hernández Rodriguez, B. Frahm, M. Lübken, M. Wichern, Chemie
    Ingenieur Technik 96 (2024) 528–534.
  ufg: '<b>Kosse, Pascal u. a.</b>: Comparative Analysis of pH Prediction Routines
    in ADM1 and a Specialized Water Chemistry Simulator, in: <i>Chemie Ingenieur Technik</i>
    96 (2024), H. 4,  S. 528–534.'
  van: Kosse P, Hernández Rodriguez T, Frahm B, Lübken M, Wichern M. Comparative Analysis
    of pH Prediction Routines in ADM1 and a Specialized Water Chemistry Simulator.
    Chemie Ingenieur Technik. 2024;96(4):528–34.
date_created: 2025-01-29T13:49:16Z
date_updated: 2025-06-25T12:42:09Z
department:
- _id: DEP4000
doi: 10.1002/cite.202300188
external_id:
  isi:
  - '001169606600001'
intvolume: '        96'
isi: '1'
issue: '4'
keyword:
- Anaerobic Digestion Model No. 1 (ADM1)
- Anaerobic technology
- pH simulation
- Uncertainty assessment
- Visual Water
language:
- iso: eng
page: 528-534
place: Weinheim
publication: Chemie Ingenieur Technik
publication_identifier:
  eissn:
  - 1522-2640
  issn:
  - 0009-286X
publication_status: published
publisher: Wiley
quality_controlled: '1'
status: public
title: Comparative Analysis of pH Prediction Routines in ADM1 and a Specialized Water
  Chemistry Simulator
type: scientific_journal_article
user_id: '83781'
volume: 96
year: '2024'
...