<?xml version="1.0" encoding="UTF-8"?>

<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3">

<genre>thesis</genre>

<titleInfo><title>Contactless CAN interface for rail topologies</title></titleInfo>


<note type="publicationStatus">published</note>

<note type="internalNote">CHe</note>



<name type="personal">
  <namePart type="given">Derk</namePart>
  <namePart type="family">Wesemann</namePart>
  <role><roleTerm type="text">author</roleTerm> </role><identifier type="local">1273</identifier></name>
<name type="personal">
  <namePart type="given">Stefan</namePart>
  <namePart type="family">Wiite</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>
<name type="personal">
  <namePart type="given">Helmut</namePart>
  <namePart type="family">Bleikirch</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>







<name type="corporate">
  <namePart></namePart>
  <identifier type="local">DEP5000</identifier>
  <role>
    <roleTerm type="text">department</roleTerm>
  </role>
</name>

<name type="corporate">
  <namePart></namePart>
  <identifier type="local">DEP5023</identifier>
  <role>
    <roleTerm type="text">department</roleTerm>
  </role>
</name>



<name type="conference">
  <namePart> 13th international CAN Conference</namePart>
</name>






<abstract lang="eng">Contactless interfaces are essential to different applications which rely on physical robustness and / or high modularity and movability. This work presents a solution for direct conversion of CAN signals for contactless capacitive coupling over an air gap. The coupling distances are short (in the range of less than 1 mm), but can be extended by a supporting rail which contains coupling electrodes and conductors to deliver the signals also over larger distances. A modulation scheme is implemented to maintain the functionality of dominant and recessive bit status. No additional controller is needed; the transceiver module replaces the CAN transceiver typically added to any microcontroller. </abstract>

<originInfo><publisher>CiA</publisher><dateIssued encoding="w3cdtf">2012</dateIssued><place><placeTerm type="text">Hambach castle, Germany</placeTerm></place>
</originInfo>
<language><languageTerm authority="iso639-2b" type="code">ger</languageTerm>
</language>



<relatedItem type="host"><titleInfo><title> 13th international CAN Conference - ICC</title></titleInfo>
<part>
</part>
</relatedItem>


<extension>
<bibliographicCitation>
<bjps>&lt;b&gt;Wesemann D, Wiite S and Bleikirch H&lt;/b&gt; (2012) &lt;i&gt;Contactless CAN interface for rail topologies&lt;/i&gt;. Nürnberg: CiA.</bjps>
<chicago-de>Wesemann, Derk, Stefan Wiite und Helmut Bleikirch. 2012. &lt;i&gt;Contactless CAN interface for rail topologies&lt;/i&gt;. &lt;i&gt; 13th international CAN Conference - ICC&lt;/i&gt;. Nürnberg: CiA.</chicago-de>
<ama>Wesemann D, Wiite S, Bleikirch H. &lt;i&gt;Contactless CAN interface for rail topologies&lt;/i&gt;. CiA; 2012.</ama>
<havard>D. Wesemann, S. Wiite, H. Bleikirch, Contactless CAN interface for rail topologies, CiA, Nürnberg, 2012.</havard>
<mla>Wesemann, Derk, et al. “Contactless CAN interface for rail topologies.” &lt;i&gt; 13th international CAN Conference - ICC&lt;/i&gt;, CiA, 2012.</mla>
<ufg>&lt;b&gt;Wesemann, Derk/Wiite, Stefan/Bleikirch, Helmut&lt;/b&gt;: Contactless CAN interface for rail topologies, Nürnberg 2012.</ufg>
<apa>Wesemann, D., Wiite, S., &amp;#38; Bleikirch, H. (2012). Contactless CAN interface for rail topologies. In &lt;i&gt; 13th international CAN Conference - ICC&lt;/i&gt;.  13th international CAN Conference, Hambach castle, Germany. CiA.</apa>
<van>Wesemann D, Wiite S, Bleikirch H. Contactless CAN interface for rail topologies.  13th international CAN Conference - ICC. Nürnberg: CiA; 2012.</van>
<ieee>D. Wesemann, S. Wiite, and H. Bleikirch, &lt;i&gt;Contactless CAN interface for rail topologies&lt;/i&gt;. Nürnberg: CiA, 2012.</ieee>
<chicago>Wesemann, Derk, Stefan Wiite, and Helmut Bleikirch. &lt;i&gt;Contactless CAN interface for rail topologies&lt;/i&gt;. &lt;i&gt; 13th international CAN Conference - ICC&lt;/i&gt;. Nürnberg: CiA, 2012.</chicago>
<din1505-2-1>&lt;span style=&quot;font-variant:small-caps;&quot;&gt;Wesemann, Derk&lt;/span&gt; ; &lt;span style=&quot;font-variant:small-caps;&quot;&gt;Wiite, Stefan&lt;/span&gt; ; &lt;span style=&quot;font-variant:small-caps;&quot;&gt;Bleikirch, Helmut&lt;/span&gt;: &lt;i&gt;Contactless CAN interface for rail topologies&lt;/i&gt;. Nürnberg : CiA, 2012</din1505-2-1>
<short>D. Wesemann, S. Wiite, H. Bleikirch, Contactless CAN interface for rail topologies, CiA, Nürnberg, 2012.</short>
</bibliographicCitation>
</extension>
<recordInfo><recordIdentifier>10162</recordIdentifier><recordCreationDate encoding="w3cdtf">2023-07-27T10:47:10Z</recordCreationDate><recordChangeDate encoding="w3cdtf">2023-08-03T13:03:54Z</recordChangeDate>
</recordInfo>
</mods>
</modsCollection>
