res:
  bibo_abstract:
  - In anaerobic technology, pH values are crucial for targeted volatile fatty acid
    production. While pH dynamics can be modeled using the Anaerobic Digestion Model
    No. 1 (ADM1), simulation results may be biased. To address this issue, the pH
    prediction routine of Visual Water, a specialized water chemistry simulator, was
    validated. Unlike ADM1, it accounts for ionic strength and activities while also
    providing an automated uncertainty analysis. The analysis revealed Visual Water
    simulations to better fit measured pH data from acidic solutions in a miniaturized
    stirred-tank reactor.@eng
  bibo_authorlist:
  - foaf_Person:
      foaf_givenName: Pascal
      foaf_name: Kosse, Pascal
      foaf_surname: Kosse
  - foaf_Person:
      foaf_givenName: Tanja
      foaf_name: Hernández Rodriguez, Tanja
      foaf_surname: Hernández Rodriguez
      foaf_workInfoHomepage: http://www.librecat.org/personId=52466
  - foaf_Person:
      foaf_givenName: Björn
      foaf_name: Frahm, Björn
      foaf_surname: Frahm
      foaf_workInfoHomepage: http://www.librecat.org/personId=45666
  - foaf_Person:
      foaf_givenName: Manfred
      foaf_name: Lübken, Manfred
      foaf_surname: Lübken
  - foaf_Person:
      foaf_givenName: Marc
      foaf_name: Wichern, Marc
      foaf_surname: Wichern
  bibo_doi: 10.1002/cite.202300188
  bibo_issue: '4'
  bibo_volume: 96
  dct_date: 2024^xs_gYear
  dct_identifier:
  - UT:001169606600001
  dct_isPartOf:
  - http://id.crossref.org/issn/0009-286X
  - http://id.crossref.org/issn/1522-2640
  dct_language: eng
  dct_publisher: Wiley@
  dct_subject:
  - Anaerobic Digestion Model No. 1 (ADM1)
  - Anaerobic technology
  - pH simulation
  - Uncertainty assessment
  - Visual Water
  dct_title: Comparative Analysis of pH Prediction Routines in ADM1 and a Specialized
    Water Chemistry Simulator@
...