   	<dc:title>Approach of an Active Device Protection for Drive Inverters against Short Circuit Faults in an Open Industrial DC Grid</dc:title>
   	<dc:creator>Puls, Simon</dc:creator>
   	<dc:creator>Obernolte, Urs</dc:creator>
   	<dc:creator>Borcherding, Holger</dc:creator>
   	<dc:creator>Ehlich, Martin</dc:creator>
   	<dc:subject>DC grid</dc:subject>
   	<dc:subject>fault handling strategy</dc:subject>
   	<dc:subject>DC-power supply</dc:subject>
   	<dc:subject>active protection</dc:subject>
   	<dc:subject>drive inverters</dc:subject>
   	<dc:description>An open industrial DC grid has a lot of advantages. Also new challenges arise by coupling several DC link capacitors of inverters. This paper presents an approach and measurements of an active device protection to withstand possible faults that can occur in the DC grid. In particular, robustness in the event of faults plays a key role.</dc:description>
   	<dc:publisher>IEEE</dc:publisher>
   	<dc:date>2020</dc:date>
   	<dc:type>info:eu-repo/semantics/other</dc:type>
   	<dc:type>doc-type:other</dc:type>
   	<dc:type>text</dc:type>
   	<dc:type>http://purl.org/coar/resource_type/c_1843</dc:type>
   	<dc:identifier>https://www.th-owl.de/elsa/record/4918</dc:identifier>
   	<dc:source>Puls S, Obernolte U, Borcherding H, Ehlich M. &lt;i&gt;Approach of an Active Device Protection for Drive Inverters against Short Circuit Faults in an Open Industrial DC Grid&lt;/i&gt;. IEEE; 2020. doi:&lt;a href=&quot;https://doi.org/10.23919/EPE20ECCEEurope43536.2020.9215949&quot;&gt;10.23919/EPE20ECCEEurope43536.2020.9215949&lt;/a&gt;</dc:source>
   	<dc:language>eng</dc:language>
   	<dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.23919/EPE20ECCEEurope43536.2020.9215949</dc:relation>
   	<dc:relation>info:eu-repo/semantics/altIdentifier/issn/2325-0313</dc:relation>
   	<dc:relation>info:eu-repo/semantics/altIdentifier/isbn/978-1-7281-9807-1</dc:relation>
   	<dc:rights>info:eu-repo/semantics/closedAccess</dc:rights>