Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany
T. Vollmer, M. Dabisch-Ruthe, M. Weinstock, C. Knabbe, J. Dreier, Transfusion 58 (2018) 1654–1664.
Download
Es wurde kein Volltext hochgeladen. Nur Publikationsnachweis!
Zeitschriftenaufsatz (wiss.)
| Veröffentlicht
| Englisch
Autor*in
Einrichtung
Abstract
BACKGROUND
Bacterial contamination of platelet concentrates (PCs) is still a major challenge in transfusion medicine. Different methodologic concepts and screening strategies have been developed and investigated concerning their usability. We evaluated the feasibility of BacT/ALERT automated culture (BacT/A, bioMérieux) with late sampling after 3 days at the earliest.
STUDY DESIGN AND METHODS
Twenty-four bacterial strains isolated from PCs and six relevant strains from reference stocks were spiked into apheresis-derived PCs (10-60 colony-forming units [CFU]/bag). Sampling was performed after 3 days, and bacterial detection was investigated using the two detection methods (BacT/A and BactiFlow [BF], bioMérieux). The maximum time-to-result of BacT/A was set to less than 12 hours.
RESULTS
All medium- or high-pathogenic strains are capable of proliferating to high titers, and 100% of contaminated samples were detected by BF and BacT/A (6 to ≤12 h incubation); lower detection rates of BacT/A were obtained within 6 hours of incubation (≤6 h: 76.2-93.4%). The majority of low-pathogenic isolates are also capable of growing in PCs (89.7%), showing a detection rate of 74.3% for BF versus 54.3% for BacT/A (6 to ≤12 h incubation). BacT/A failed to detect bacteria within 6 hours of incubation. Certainly, a small number of strains did not grow under PC storage conditions and were detectable by BacT/A only with increased detection times.
CONCLUSIONS
Late sampling after 3 days at the earliest, combined with reduced BacT/A incubation following the negative-to-date concept, offer an alternative opportunity to extend the shelf life of PCs from 4 to 5 days in Germany. The sensitivity of BacT/A with late sampling is nearly comparable to BF; the time-to-result is considerably longer.
Erscheinungsjahr
Zeitschriftentitel
Transfusion
Band
58
Zeitschriftennummer
7
Seite
1654-1664
ISSN
eISSN
ELSA-ID
Zitieren
Vollmer T, Dabisch-Ruthe M, Weinstock M, Knabbe C, Dreier J. Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany. Transfusion. 2018;58(7):1654-1664. doi:10.1111/trf.14617
Vollmer, T., Dabisch-Ruthe, M., Weinstock, M., Knabbe, C., & Dreier, J. (2018). Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany. Transfusion, 58(7), 1654–1664. https://doi.org/10.1111/trf.14617
Vollmer T et al. (2018) Late Sampling for Automated Culture to Extend the Platelet Shelf Life to 5 Days in Germany. Transfusion 58, 1654–1664.
Vollmer, Tanja, Mareike Dabisch-Ruthe, Melanie Weinstock, Cornelius Knabbe, and Jens Dreier. “Late Sampling for Automated Culture to Extend the Platelet Shelf Life to 5 Days in Germany.” Transfusion 58, no. 7 (2018): 1654–64. https://doi.org/10.1111/trf.14617.
Vollmer, Tanja, Mareike Dabisch-Ruthe, Melanie Weinstock, Cornelius Knabbe und Jens Dreier. 2018. Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany. Transfusion 58, Nr. 7: 1654–1664. doi:10.1111/trf.14617, .
Vollmer, Tanja ; Dabisch-Ruthe, Mareike ; Weinstock, Melanie ; Knabbe, Cornelius ; Dreier, Jens: Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany. In: Transfusion Bd. 58. Oxford [u.a.] , Wiley-Blackwell (2018), Nr. 7, S. 1654–1664
T. Vollmer, M. Dabisch-Ruthe, M. Weinstock, C. Knabbe, J. Dreier, Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany, Transfusion. 58 (2018) 1654–1664.
T. Vollmer, M. Dabisch-Ruthe, M. Weinstock, C. Knabbe, and J. Dreier, “Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany,” Transfusion, vol. 58, no. 7, pp. 1654–1664, 2018, doi: 10.1111/trf.14617.
Vollmer, Tanja, et al. “Late Sampling for Automated Culture to Extend the Platelet Shelf Life to 5 Days in Germany.” Transfusion, vol. 58, no. 7, 2018, pp. 1654–64, https://doi.org/10.1111/trf.14617.
Vollmer, Tanja u. a.: Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany, in: Transfusion 58 (2018), H. 7, S. 1654–1664.
Vollmer T, Dabisch-Ruthe M, Weinstock M, Knabbe C, Dreier J. Late sampling for automated culture to extend the platelet shelf life to 5 days in Germany. Transfusion. 2018;58(7):1654–64.