Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture
S. Uhlendorff, U. Odefey, B. Frahm, M. Pein-Hackelbusch, Chemie Ingenieur Technik (2025).
Zeitschriftenaufsatz (wiss.)
| Veröffentlicht
| Englisch
Autor*in
Einrichtung
Abstract
Determining cell density and viability with (semi‐)automated methods enables rapid cell cultivation analysis. However, scientific validation is required, typically by comparing results to manual counting. To address this, we present a method to evaluate and compare two cell counting methods exemplified by a manual and a semi‐automated method (Countstar BioTech). Experiments followed validation parameters aligned with the International Council for Harmonization (ICH) Q2(R1) guideline and a dilution series design based on ISO 20391‐2:2019. Both the semi‐automated and manual methods showed comparable specificity and linearity for Chinese hamster ovary (CHO)‐K1 cells. The semi‐automated method exhibited superior repeatability for total cell density, whereas cell viability results showed no significant difference.
Stichworte
Erscheinungsjahr
Zeitschriftentitel
Chemie Ingenieur Technik
Artikelnummer
cite.70048
ISSN
eISSN
ELSA-ID
Zitieren
Uhlendorff S, Odefey U, Frahm B, Pein-Hackelbusch M. Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture. Chemie Ingenieur Technik. Published online 2025. doi:10.1002/cite.70048
Uhlendorff, S., Odefey, U., Frahm, B., & Pein-Hackelbusch, M. (2025). Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture. Chemie Ingenieur Technik, Article cite. 70048. https://doi.org/10.1002/cite.70048
Uhlendorff S et al. (2025) Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture. Chemie Ingenieur Technik.
Uhlendorff, Selina, Ulrich Odefey, Björn Frahm, and Miriam Pein-Hackelbusch. “Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture.” Chemie Ingenieur Technik, 2025. https://doi.org/10.1002/cite.70048.
Uhlendorff, Selina, Ulrich Odefey, Björn Frahm und Miriam Pein-Hackelbusch. 2025. Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture. Chemie Ingenieur Technik. doi:10.1002/cite.70048, .
Uhlendorff, Selina ; Odefey, Ulrich ; Frahm, Björn ; Pein-Hackelbusch, Miriam: Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture. In: Chemie Ingenieur Technik. Weinheim, Wiley (2025)
S. Uhlendorff, U. Odefey, B. Frahm, M. Pein-Hackelbusch, Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture, Chemie Ingenieur Technik. (2025).
S. Uhlendorff, U. Odefey, B. Frahm, and M. Pein-Hackelbusch, “Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture,” Chemie Ingenieur Technik, Art. no. cite. 70048, 2025, doi: 10.1002/cite.70048.
Uhlendorff, Selina, et al. “Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture.” Chemie Ingenieur Technik, cite. 70048, 2025, https://doi.org/10.1002/cite.70048.
Uhlendorff, Selina u. a.: Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture, in: Chemie Ingenieur Technik (2025).
Uhlendorff S, Odefey U, Frahm B, Pein-Hackelbusch M. Performance Comparison between Semi‐Automated and Manual Cell Counting for Animal Cell Culture. Chemie Ingenieur Technik. 2025;
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Erklärung zum Urheberrecht:
Dieses Dokument ist vom Urheberrecht geschützt [...]
Link(s) zu Volltext(en)
Access Level
Closed Access
